  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 583840,
    "TruckloadIDCQ": 681389,
    "Truckload_Number": "1990034811",
    "Batching_DateTime_UTC": "2026-03-27T08:05:28Z",
    "LoadStart_UTC": "2026-03-27T08:05:28Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-03-27T09:43:00Z",
    "PourEnd_UTC": "2026-03-27T10:39:00Z",
    "AtJobsite_UTC": "2026-03-27T09:30:00Z",
    "ToJobsite_UTC": "2026-03-27T08:20:34Z",
    "ToPlant_UTC": "2026-03-27T10:40:18Z",
    "AtPlant_UTC": "2026-03-27T11:47:58Z",
    "Batching_Volume": 7.5,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 7233,
    "Truck_Code": "3085ndn",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 681275,
    "Jobsite_ID": "0082296308",
    "Jobsite_Description": "CO TIENDA CONSUN OCA?A",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "GABICAD CONSTRUCCION, S.L",
    "Jobsite_Lat": -3.488203,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 658342,
    "MixDesign_ID": "20000102",
    "MixDesign_Code": "X-300-0-S-28-05-0-S-XXX",
    "MixDesign_Description": "AUTOLEVEL ESTANDAR",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": {
      "DateFrom": "1900-01-01T00:00:00Z",
      "DateTo": "2100-01-01T00:00:00Z",
      "TargetValue": 225.0,
      "TargetUnitID": 203,
      "TargetUnitXID": 0,
      "Boundaries": {
        "LO_OUT": null,
        "LO_DANGER": 205.0,
        "LO_WARNING": null,
        "HI_WARNING": null,
        "HI_DANGER": 245.0,
        "HI_OUT": null
      },
      "Ranges": [
        {
          "From": 205.0,
          "To": 245.0,
          "Expr": "OK"
        }
      ]
    },
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": "MM",
    "MixDesign_Target_Slump": 225.0,
    "MixDesign_Target_Slump_Unit": "MM",
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.8134767,
    "Components": [
      {
        "MaterialIDCQ": 651478,
        "Material_ID": "1401452811",
        "Material_Code": "R06",
        "Material_Name": "CENTRAMENT SRA 1",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 2.89,
        "Quantity_Target_SSD": 21.675,
        "Quantity_Target_Adjusted": 21.675,
        "Quantity_Actual": 19.4,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 641052,
        "Material_ID": "1401282832",
        "Material_Code": "C20",
        "Material_Name": "CX ISOTARD 001",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 0.4,
        "Quantity_Target_SSD": 3.0,
        "Quantity_Target_Adjusted": 3.0,
        "Quantity_Actual": 3.0,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 641061,
        "Material_ID": "1401448533",
        "Material_Code": "S42",
        "Material_Name": "CX ISOFLEX 741",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 2.5,
        "Quantity_Target_SSD": 18.75,
        "Quantity_Target_Adjusted": 18.75,
        "Quantity_Actual": 18.7,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 636443,
        "Material_ID": "1401451995",
        "Material_Code": "Q04",
        "Material_Name": "CX ISOSTAB 6003",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 0.5,
        "Quantity_Target_SSD": 3.75,
        "Quantity_Target_Adjusted": 3.75,
        "Quantity_Actual": 3.6,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 636457,
        "Material_ID": "82",
        "Material_Code": "A1",
        "Material_Name": "AGUA LIMPIA",
        "Material_Type": "water",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 290.0,
        "Quantity_Target_SSD": 1819.74,
        "Quantity_Target_Adjusted": 1819.74,
        "Quantity_Actual": 1815.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 636466,
        "Material_ID": "1400622483",
        "Material_Code": "AC2",
        "Material_Name": "ARENA,CALIZA 02,0 - 4 MM,84 %,HUMEDAD 1",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 460.0,
        "Quantity_Target_SSD": 3450.0,
        "Quantity_Target_Adjusted": 3450.0,
        "Quantity_Actual": 3518.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 641054,
        "Material_ID": "1400623421",
        "Material_Code": "AS1",
        "Material_Name": "ARENA,SILICE 01,0/2 MM,92 %,HUMEDAD 1-3",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 900.0,
        "Quantity_Target_SSD": 6749.997,
        "Quantity_Target_Adjusted": 7105.26,
        "Quantity_Actual": 7092.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.05,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 636477,
        "Material_ID": "1401454366",
        "Material_Code": "CS",
        "Material_Name": "CEM. II/B-M (P-LL) 42.5 R",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 365.0,
        "Quantity_Target_SSD": 2737.5,
        "Quantity_Target_Adjusted": 2737.5,
        "Quantity_Actual": 2754.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 658211,
        "Material_ID": "1401450898",
        "Material_Code": "F35",
        "Material_Name": "FIBRA POLIPROPILENO",
        "Material_Type": "fibre",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1.0,
        "Quantity_Target_SSD": 4.5,
        "Quantity_Target_Adjusted": 4.5,
        "Quantity_Actual": 0.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}