{
  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 600906,
    "TruckloadIDCQ": 655970,
    "Truckload_Number": "20066587",
    "Batching_DateTime_UTC": "2026-01-23T08:45:06Z",
    "LoadStart_UTC": "2026-01-23T08:45:06Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-01-23T09:40:42Z",
    "PourEnd_UTC": "2026-01-23T10:05:05Z",
    "AtJobsite_UTC": "2026-01-23T09:25:28Z",
    "ToJobsite_UTC": "2026-01-23T09:01:48Z",
    "ToPlant_UTC": "2026-01-23T10:18:38Z",
    "AtPlant_UTC": "2026-01-23T10:46:08Z",
    "Batching_Volume": 7.0,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 7222,
    "Truck_Code": "8160MWX",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 651562,
    "Jobsite_ID": "0082191444",
    "Jobsite_Description": "CO CG0C FLEXY EDIFICIO C",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "FERROVIAL CONSTRUCCION S.A.",
    "Jobsite_Lat": -3.610107,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 655969,
    "MixDesign_ID": "20368786",
    "MixDesign_Code": "2-025-4-C-28-03-0-S-A00-C2",
    "MixDesign_Description": "HA-25/B/20/XC2 PENETRON",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": {
      "DateFrom": "1900-01-01T00:00:00Z",
      "DateTo": "2100-01-01T00:00:00Z",
      "TargetValue": 125.0,
      "TargetUnitID": 203,
      "TargetUnitXID": 0,
      "Boundaries": {
        "LO_OUT": null,
        "LO_DANGER": 105.0,
        "LO_WARNING": null,
        "HI_WARNING": null,
        "HI_DANGER": 145.0,
        "HI_OUT": null
      },
      "Ranges": [
        {
          "From": 105.0,
          "To": 145.0,
          "Expr": "OK"
        }
      ]
    },
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": "MM",
    "MixDesign_Target_Slump": 125.0,
    "MixDesign_Target_Slump_Unit": "MM",
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.5260351,
    "Components": [
      {
        "MaterialIDCQ": 655967,
        "Material_ID": "1401455439",
        "Material_Code": "E27",
        "Material_Name": "PENETRON ADMIX",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 3.0,
        "Quantity_Target_SSD": 21.0,
        "Quantity_Target_Adjusted": 21.0,
        "Quantity_Actual": 0.0,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 634785,
        "Material_ID": "1401453951",
        "Material_Code": "A60",
        "Material_Name": "MASTER POZZOLITH 477N",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1.04,
        "Quantity_Target_SSD": 7.28,
        "Quantity_Target_Adjusted": 7.28,
        "Quantity_Actual": 7.3,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 634783,
        "Material_ID": "1401455636",
        "Material_Code": "S76",
        "Material_Name": "MASTERCORE 3355",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 3.16,
        "Quantity_Target_SSD": 22.12,
        "Quantity_Target_Adjusted": 22.12,
        "Quantity_Actual": 22.148,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 640823,
        "Material_ID": "1401282833",
        "Material_Code": "N09",
        "Material_Name": "CX ISOFROST 001",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1.25,
        "Quantity_Target_SSD": 8.75,
        "Quantity_Target_Adjusted": 8.75,
        "Quantity_Actual": 8.7,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 633897,
        "Material_ID": "82",
        "Material_Code": "A1",
        "Material_Name": "AGUA LIMPIA",
        "Material_Type": "water",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 142.0,
        "Quantity_Target_SSD": 454.0,
        "Quantity_Target_Adjusted": 454.0,
        "Quantity_Actual": 451.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 634787,
        "Material_ID": "1400623424",
        "Material_Code": "AS2",
        "Material_Name": "ARENA BAJO ALCALIS",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 780.0,
        "Quantity_Target_SSD": 5460.0,
        "Quantity_Target_Adjusted": 6000.0,
        "Quantity_Actual": 6010.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.09,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 634789,
        "Material_ID": "1400622483",
        "Material_Code": "AC2",
        "Material_Name": "ARENA,CALIZA 02,0 - 4 MM,84 %,HUMEDAD 1",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 180.0,
        "Quantity_Target_SSD": 1260.0,
        "Quantity_Target_Adjusted": 1260.0,
        "Quantity_Actual": 1246.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 633901,
        "Material_ID": "1401454366",
        "Material_Code": "CS",
        "Material_Name": "CEM. II/B-M (P-LL) 42.5 R",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 285.0,
        "Quantity_Target_SSD": 1995.0,
        "Quantity_Target_Adjusted": 1995.0,
        "Quantity_Actual": 2001.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 634791,
        "Material_ID": "1400623680",
        "Material_Code": "GC4",
        "Material_Name": "GRAVA , TIPO CALIZA, GRANULOMETRIA 12-20",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 960.0,
        "Quantity_Target_SSD": 6720.0,
        "Quantity_Target_Adjusted": 6720.0,
        "Quantity_Actual": 6731.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}