  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 655185,
    "Truckload_Number": "24651827",
    "Batching_DateTime_UTC": "2026-01-12T12:15:50Z",
    "LoadStart_UTC": "2026-01-12T12:15:50Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-01-12T12:50:00Z",
    "PourEnd_UTC": "2026-01-12T13:20:00Z",
    "AtJobsite_UTC": "2026-01-12T12:45:00Z",
    "ToJobsite_UTC": "2026-01-12T12:22:04Z",
    "ToPlant_UTC": "2026-01-12T13:26:21Z",
    "AtPlant_UTC": "2026-01-12T13:51:08Z",
    "Batching_Volume": 4.5,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6510,
    "Truck_Code": "2553MWG",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 681043,
    "Jobsite_ID": "0065520422",
    "Jobsite_Description": "CO H02045 HORMIGON MOLI DE ANIMETA",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "CHM OBRAS E INFRAESTRUCTURAS, S.A.",
    "Jobsite_Lat": -0.43331,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 655184,
    "MixDesign_ID": "HA-30/P/20/XS2 SR",
    "MixDesign_Code": "HA-30/P/20/XS2 SR",
    "MixDesign_Description": "HA-30/P/20/XS2 SR",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": null,
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": null,
    "MixDesign_Target_Slump": null,
    "MixDesign_Target_Slump_Unit": null,
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.3136092,
    "Components": [
      {
        "MaterialIDCQ": 675685,
        "Material_ID": "1401452407",
        "Material_Code": "S60",
        "Material_Name": "CX ISOFLEX 742",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 2.18,
        "Quantity_Target_SSD": 9.81,
        "Quantity_Target_Adjusted": 9.81,
        "Quantity_Actual": 9.8,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675687,
        "Material_ID": "1401451800",
        "Material_Code": "A55",
        "Material_Name": "CX ISOPLAST 1800",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1.09,
        "Quantity_Target_SSD": 4.904,
        "Quantity_Target_Adjusted": 4.904,
        "Quantity_Actual": 4.9,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675689,
        "Material_ID": "82",
        "Material_Code": "A1",
        "Material_Name": "AGUA LIMPIA",
        "Material_Type": "water",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 120.0,
        "Quantity_Target_SSD": 461.476,
        "Quantity_Target_Adjusted": 461.476,
        "Quantity_Actual": 3262.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675691,
        "Material_ID": "1401453146",
        "Material_Code": "AC2NP",
        "Material_Name": "ARENA CALIZA 04 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 954.0,
        "Quantity_Target_SSD": 4293.94284,
        "Quantity_Target_Adjusted": 4337.316,
        "Quantity_Actual": 4342.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.01,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675765,
        "Material_ID": "1400618683",
        "Material_Code": "C4",
        "Material_Name": "CEMENTO RESISTENTE III/A 42,5 N/SR",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 327.0,
        "Quantity_Target_SSD": 1471.5,
        "Quantity_Target_Adjusted": 1471.5,
        "Quantity_Actual": 1474.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675699,
        "Material_ID": "1401453149",
        "Material_Code": "GC4NP",
        "Material_Name": "GRAVA CALIZA 12/20 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 773.0,
        "Quantity_Target_SSD": 3479.85,
        "Quantity_Target_Adjusted": 3515.0,
        "Quantity_Actual": 3527.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.01,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675697,
        "Material_ID": "1401453148",
        "Material_Code": "GC2NP",
        "Material_Name": "GRAVA 6/12 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 271.0,
        "Quantity_Target_SSD": 1218.33,
        "Quantity_Target_Adjusted": 1218.33,
        "Quantity_Actual": 1217.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}