  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 676087,
    "Truckload_Number": "24652662",
    "Batching_DateTime_UTC": "2026-02-03T15:47:42Z",
    "LoadStart_UTC": "2026-02-03T15:47:42Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-02-03T16:22:00Z",
    "PourEnd_UTC": "2026-02-03T17:00:00Z",
    "AtJobsite_UTC": "2026-02-03T16:12:00Z",
    "ToJobsite_UTC": "2026-02-03T16:04:26Z",
    "ToPlant_UTC": "2026-02-03T17:00:25Z",
    "AtPlant_UTC": "2026-02-03T17:19:58Z",
    "Batching_Volume": 2.0,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6517,
    "Truck_Code": "2772MFY",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 675948,
    "Jobsite_ID": "0082296155",
    "Jobsite_Description": "CO PATERNA OBRA 25061 ONILSA",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "HORMIPRESA NEC, S.L.",
    "Jobsite_Lat": -0.44637,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 642724,
    "MixDesign_ID": "HA-35/F/12/XC1",
    "MixDesign_Code": "HA-35/F/12/XC1",
    "MixDesign_Description": "HA-35/F/12/XC1",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": null,
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": null,
    "MixDesign_Target_Slump": null,
    "MixDesign_Target_Slump_Unit": null,
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.3793094,
    "Components": [
      {
        "MaterialIDCQ": 675685,
        "Material_ID": "1401452407",
        "Material_Code": "S60",
        "Material_Name": "CX ISOFLEX 742",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 4.37,
        "Quantity_Target_SSD": 8.74,
        "Quantity_Target_Adjusted": 8.74,
        "Quantity_Actual": 8.7,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675687,
        "Material_ID": "1401451800",
        "Material_Code": "A55",
        "Material_Name": "CX ISOPLAST 1800",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1.19,
        "Quantity_Target_SSD": 2.38,
        "Quantity_Target_Adjusted": 2.38,
        "Quantity_Actual": 2.4,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675689,
        "Material_ID": "82",
        "Material_Code": "A1",
        "Material_Name": "AGUA LIMPIA",
        "Material_Type": "water",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 135.0,
        "Quantity_Target_SSD": 270.0,
        "Quantity_Target_Adjusted": 270.0,
        "Quantity_Actual": 1728.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675691,
        "Material_ID": "1401453146",
        "Material_Code": "AC2NP",
        "Material_Name": "ARENA CALIZA 04 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 934.0,
        "Quantity_Target_SSD": 1868.32,
        "Quantity_Target_Adjusted": 1868.32,
        "Quantity_Actual": 1941.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675695,
        "Material_ID": "1401455211",
        "Material_Code": "CG1",
        "Material_Name": "CEM II/B-M (S-L) 42,5 R",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 356.0,
        "Quantity_Target_SSD": 711.82,
        "Quantity_Target_Adjusted": 711.82,
        "Quantity_Actual": 716.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675697,
        "Material_ID": "1401453148",
        "Material_Code": "GC2NP",
        "Material_Name": "GRAVA 6/12 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 967.0,
        "Quantity_Target_SSD": 1933.38,
        "Quantity_Target_Adjusted": 1933.38,
        "Quantity_Actual": 1942.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}