  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 676217,
    "Truckload_Number": "24653001",
    "Batching_DateTime_UTC": "2026-02-16T07:17:42Z",
    "LoadStart_UTC": "2026-02-16T07:17:42Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-02-16T08:12:00Z",
    "PourEnd_UTC": "2026-02-16T08:46:00Z",
    "AtJobsite_UTC": "2026-02-16T08:04:00Z",
    "ToJobsite_UTC": "2026-02-16T07:29:43Z",
    "ToPlant_UTC": "2026-02-16T08:46:54Z",
    "AtPlant_UTC": "2026-02-16T09:18:29Z",
    "Batching_Volume": 7.5,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6517,
    "Truck_Code": "2772MFY",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 675704,
    "Jobsite_ID": "0082236092",
    "Jobsite_Description": "CO TORRENT BARRANCO DE LA HORTETA",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "OCIDE CONSTRUCCION,S.A.",
    "Jobsite_Lat": -0.4936463,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 622766,
    "MixDesign_ID": "HM-20/B/20/X0",
    "MixDesign_Code": "HM-20/B/20/X0",
    "MixDesign_Description": "HM-20/B/20/X0",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": null,
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": null,
    "MixDesign_Target_Slump": null,
    "MixDesign_Target_Slump_Unit": null,
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.5607074,
    "Components": [
      {
        "MaterialIDCQ": 675687,
        "Material_ID": "1401451800",
        "Material_Code": "A55",
        "Material_Name": "CX ISOPLAST 1800",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 0.77,
        "Quantity_Target_SSD": 5.775,
        "Quantity_Target_Adjusted": 5.775,
        "Quantity_Actual": 5.8,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675685,
        "Material_ID": "1401452407",
        "Material_Code": "S60",
        "Material_Name": "CX ISOFLEX 742",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 2.87,
        "Quantity_Target_SSD": 21.525,
        "Quantity_Target_Adjusted": 21.525,
        "Quantity_Actual": 21.5,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675689,
        "Material_ID": "82",
        "Material_Code": "A1",
        "Material_Name": "AGUA LIMPIA",
        "Material_Type": "water",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 130.0,
        "Quantity_Target_SSD": 975.0,
        "Quantity_Target_Adjusted": 975.0,
        "Quantity_Actual": 6867.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675691,
        "Material_ID": "1401453146",
        "Material_Code": "AC2NP",
        "Material_Name": "ARENA CALIZA 04 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1020.0,
        "Quantity_Target_SSD": 7651.725,
        "Quantity_Target_Adjusted": 7651.725,
        "Quantity_Actual": 7644.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675695,
        "Material_ID": "1401455211",
        "Material_Code": "CG1",
        "Material_Name": "CEM II/B-M (S-L) 42,5 R",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 232.0,
        "Quantity_Target_SSD": 1738.875,
        "Quantity_Target_Adjusted": 1738.875,
        "Quantity_Actual": 1721.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675699,
        "Material_ID": "1401453149",
        "Material_Code": "GC4NP",
        "Material_Name": "GRAVA CALIZA 12/20 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 736.0,
        "Quantity_Target_SSD": 5520.9,
        "Quantity_Target_Adjusted": 5520.9,
        "Quantity_Actual": 5527.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675697,
        "Material_ID": "1401453148",
        "Material_Code": "GC2NP",
        "Material_Name": "GRAVA 6/12 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 258.0,
        "Quantity_Target_SSD": 1932.9,
        "Quantity_Target_Adjusted": 1932.9,
        "Quantity_Actual": 1930.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}