  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 676259,
    "Truckload_Number": "24653126",
    "Batching_DateTime_UTC": "2026-02-18T07:11:19Z",
    "LoadStart_UTC": "2026-02-18T07:11:19Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-02-18T09:38:00Z",
    "PourEnd_UTC": "2026-02-18T11:45:00Z",
    "AtJobsite_UTC": "2026-02-18T07:51:00Z",
    "ToJobsite_UTC": "2026-02-18T07:20:29Z",
    "ToPlant_UTC": "2026-02-18T11:46:02Z",
    "AtPlant_UTC": "2026-02-18T11:57:37Z",
    "Batching_Volume": 7.0,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6514,
    "Truck_Code": "9124MRX",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 675756,
    "Jobsite_ID": "0082209889",
    "Jobsite_Description": "CO PATERNA 941 HOSPITAL VETERINARIO",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "INMOKING SERV. TECN Y CONST. ,SL",
    "Jobsite_Lat": -0.446628,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 622687,
    "MixDesign_ID": "HA-25/B/20/XC2",
    "MixDesign_Code": "HA-25/B/20/XC2",
    "MixDesign_Description": "HA-25/B/20/XC2",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": null,
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": null,
    "MixDesign_Target_Slump": null,
    "MixDesign_Target_Slump_Unit": null,
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.4693136,
    "Components": [
      {
        "MaterialIDCQ": 675687,
        "Material_ID": "1401451800",
        "Material_Code": "A55",
        "Material_Name": "CX ISOPLAST 1800",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 0.92,
        "Quantity_Target_SSD": 6.441,
        "Quantity_Target_Adjusted": 6.441,
        "Quantity_Actual": 6.4,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675685,
        "Material_ID": "1401452407",
        "Material_Code": "S60",
        "Material_Name": "CX ISOFLEX 742",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 2.69,
        "Quantity_Target_SSD": 18.831,
        "Quantity_Target_Adjusted": 18.831,
        "Quantity_Actual": 18.8,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675689,
        "Material_ID": "82",
        "Material_Code": "A1",
        "Material_Name": "AGUA LIMPIA",
        "Material_Type": "water",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 130.0,
        "Quantity_Target_SSD": 909.999,
        "Quantity_Target_Adjusted": 909.999,
        "Quantity_Actual": 6419.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675691,
        "Material_ID": "1401453146",
        "Material_Code": "AC2NP",
        "Material_Name": "ARENA CALIZA 04 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1028.0,
        "Quantity_Target_SSD": 7197.819,
        "Quantity_Target_Adjusted": 7197.819,
        "Quantity_Actual": 7254.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675695,
        "Material_ID": "1401455211",
        "Material_Code": "CG1",
        "Material_Name": "CEM II/B-M (S-L) 42,5 R",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 277.0,
        "Quantity_Target_SSD": 1938.999,
        "Quantity_Target_Adjusted": 1938.999,
        "Quantity_Actual": 1940.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675697,
        "Material_ID": "1401453148",
        "Material_Code": "GC2NP",
        "Material_Name": "GRAVA 6/12 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 239.0,
        "Quantity_Target_SSD": 1671.81,
        "Quantity_Target_Adjusted": 1671.81,
        "Quantity_Actual": 1680.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675699,
        "Material_ID": "1401453149",
        "Material_Code": "GC4NP",
        "Material_Name": "GRAVA CALIZA 12/20 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 682.0,
        "Quantity_Target_SSD": 4776.099,
        "Quantity_Target_Adjusted": 4776.099,
        "Quantity_Actual": 4777.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}