  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 676268,
    "Truckload_Number": "24653156",
    "Batching_DateTime_UTC": "2026-02-18T12:09:15Z",
    "LoadStart_UTC": "2026-02-18T12:09:15Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-02-18T12:56:00Z",
    "PourEnd_UTC": "2026-02-18T13:38:00Z",
    "AtJobsite_UTC": "2026-02-18T12:48:00Z",
    "ToJobsite_UTC": "2026-02-18T12:26:16Z",
    "ToPlant_UTC": "2026-02-18T13:39:44Z",
    "AtPlant_UTC": "2026-02-18T14:00:48Z",
    "Batching_Volume": 7.5,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6517,
    "Truck_Code": "2772MFY",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 675787,
    "Jobsite_ID": "0082253703",
    "Jobsite_Description": "CO MASSAROJOS CL CARLOS TOMAS COSTA",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "MALVARROSAPLAYA, S.L.",
    "Jobsite_Lat": -0.4131261,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 676267,
    "MixDesign_ID": "HA-25/F/12/XC1 Bomb.",
    "MixDesign_Code": "HA-25/F/12/XC1 Bomb.",
    "MixDesign_Description": "HA-25/F/12/XC1 Bomb.",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": null,
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": null,
    "MixDesign_Target_Slump": null,
    "MixDesign_Target_Slump_Unit": null,
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.5316133,
    "Components": [
      {
        "MaterialIDCQ": 675685,
        "Material_ID": "1401452407",
        "Material_Code": "S60",
        "Material_Name": "CX ISOFLEX 742",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 2.74,
        "Quantity_Target_SSD": 20.55,
        "Quantity_Target_Adjusted": 20.55,
        "Quantity_Actual": 20.5,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675687,
        "Material_ID": "1401451800",
        "Material_Code": "A55",
        "Material_Name": "CX ISOPLAST 1800",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 0.94,
        "Quantity_Target_SSD": 7.05,
        "Quantity_Target_Adjusted": 7.05,
        "Quantity_Actual": 7.0,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675693,
        "Material_ID": "1401453150",
        "Material_Code": "AC1NP",
        "Material_Name": "ARENA CALIZA 0/2 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 138.0,
        "Quantity_Target_SSD": 1038.3,
        "Quantity_Target_Adjusted": 1038.3,
        "Quantity_Actual": 1024.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675697,
        "Material_ID": "1401453148",
        "Material_Code": "GC2NP",
        "Material_Name": "GRAVA 6/12 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 815.0,
        "Quantity_Target_SSD": 6108.9,
        "Quantity_Target_Adjusted": 6108.9,
        "Quantity_Actual": 6107.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}