  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 676404,
    "Truckload_Number": "24653659",
    "Batching_DateTime_UTC": "2026-03-02T09:48:33Z",
    "LoadStart_UTC": "2026-03-02T09:48:33Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-03-02T10:16:00Z",
    "PourEnd_UTC": "2026-03-02T10:49:00Z",
    "AtJobsite_UTC": "2026-03-02T10:12:00Z",
    "ToJobsite_UTC": "2026-03-02T09:56:12Z",
    "ToPlant_UTC": "2026-03-02T10:50:13Z",
    "AtPlant_UTC": "2026-03-02T11:15:42Z",
    "Batching_Volume": 3.5,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6510,
    "Truck_Code": "2553MWG",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 675714,
    "Jobsite_ID": "0082093312",
    "Jobsite_Description": "CO PATERNA OB0690 CENTRO NAL. DOSIM",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "EDHINOR, S.A.",
    "Jobsite_Lat": -0.42385,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 655229,
    "MixDesign_ID": "HA-30/F/20/XC2",
    "MixDesign_Code": "HA-30/F/20/XC2",
    "MixDesign_Description": "HA-30/F/20/XC2",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": null,
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": null,
    "MixDesign_Target_Slump": null,
    "MixDesign_Target_Slump_Unit": null,
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.4470051,
    "Components": [
      {
        "MaterialIDCQ": 675687,
        "Material_ID": "1401451800",
        "Material_Code": "A55",
        "Material_Name": "CX ISOPLAST 1800",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1.01,
        "Quantity_Target_SSD": 3.536,
        "Quantity_Target_Adjusted": 3.536,
        "Quantity_Actual": 3.5,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675691,
        "Material_ID": "1401453146",
        "Material_Code": "AC2NP",
        "Material_Name": "ARENA CALIZA 04 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 977.0,
        "Quantity_Target_SSD": 3420.724,
        "Quantity_Target_Adjusted": 3420.724,
        "Quantity_Actual": 3413.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675697,
        "Material_ID": "1401453148",
        "Material_Code": "GC2NP",
        "Material_Name": "GRAVA 6/12 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 253.0,
        "Quantity_Target_SSD": 883.784,
        "Quantity_Target_Adjusted": 883.784,
        "Quantity_Actual": 880.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675699,
        "Material_ID": "1401453149",
        "Material_Code": "GC4NP",
        "Material_Name": "GRAVA CALIZA 12/20 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 721.0,
        "Quantity_Target_SSD": 2524.83,
        "Quantity_Target_Adjusted": 2524.83,
        "Quantity_Actual": 2522.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}