{
  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 676510,
    "Truckload_Number": "24654005",
    "Batching_DateTime_UTC": "2026-03-11T09:25:29Z",
    "LoadStart_UTC": "2026-03-11T09:25:29Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-03-11T10:35:00Z",
    "PourEnd_UTC": "2026-03-11T11:47:00Z",
    "AtJobsite_UTC": "2026-03-11T10:22:00Z",
    "ToJobsite_UTC": "2026-03-11T09:47:58Z",
    "ToPlant_UTC": "2026-03-11T11:48:26Z",
    "AtPlant_UTC": "2026-03-11T12:41:07Z",
    "Batching_Volume": 7.5,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6517,
    "Truck_Code": "2772MFY",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 676026,
    "Jobsite_ID": "0081945053",
    "Jobsite_Description": "CO MONCADA 3T50 CEU SAN PABLO",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "FCC CONSTRUCCION, S.A.",
    "Jobsite_Lat": -0.3886266,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 676089,
    "MixDesign_ID": "HA-25/L/12/XC2 Bomb.ESTATICA",
    "MixDesign_Code": "HA-25/L/12/XC2 Bomb.ESTATICA",
    "MixDesign_Description": "HA-25/L/12/XC2 Bomb.ESTATICA",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": null,
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": null,
    "MixDesign_Target_Slump": null,
    "MixDesign_Target_Slump_Unit": null,
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": 0.4975683,
    "Components": [
      {
        "MaterialIDCQ": 675838,
        "Material_ID": "1401456382",
        "Material_Code": "S82",
        "Material_Name": "ISOFLOW PRIME 9350",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 3.26,
        "Quantity_Target_SSD": 24.45,
        "Quantity_Target_Adjusted": 24.45,
        "Quantity_Actual": 24.4,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675687,
        "Material_ID": "1401451800",
        "Material_Code": "A55",
        "Material_Name": "CX ISOPLAST 1800",
        "Material_Type": "admixture",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 1.05,
        "Quantity_Target_SSD": 7.875,
        "Quantity_Target_Adjusted": 7.875,
        "Quantity_Actual": 7.9,
        "Quantity_Unit": "LITER",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675689,
        "Material_ID": "82",
        "Material_Code": "A1",
        "Material_Name": "AGUA LIMPIA",
        "Material_Type": "water",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 160.0,
        "Quantity_Target_SSD": 1175.505,
        "Quantity_Target_Adjusted": 1175.505,
        "Quantity_Actual": 8274.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675691,
        "Material_ID": "1401453146",
        "Material_Code": "AC2NP",
        "Material_Name": "ARENA CALIZA 04 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 985.0,
        "Quantity_Target_SSD": 7387.5,
        "Quantity_Target_Adjusted": 7387.5,
        "Quantity_Actual": 7377.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675693,
        "Material_ID": "1401453150",
        "Material_Code": "AC1NP",
        "Material_Name": "ARENA CALIZA 0/2 NOU PATERNA",
        "Material_Type": "fine aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 225.0,
        "Quantity_Target_SSD": 1687.5,
        "Quantity_Target_Adjusted": 1687.5,
        "Quantity_Actual": 1670.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675695,
        "Material_ID": "1401455211",
        "Material_Code": "CG1",
        "Material_Name": "CEM II/B-M (S-L) 42,5 R",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 315.0,
        "Quantity_Target_SSD": 2362.5,
        "Quantity_Target_Adjusted": 2362.5,
        "Quantity_Actual": 2361.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675697,
        "Material_ID": "1401453148",
        "Material_Code": "GC2NP",
        "Material_Name": "GRAVA 6/12 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 650.0,
        "Quantity_Target_SSD": 4874.997525,
        "Quantity_Target_Adjusted": 4899.495,
        "Quantity_Actual": 4899.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.005,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}