  "Vendor": "CEMEX",
  "Secret": "6af3e11d-b1a5-42cc-b95e-4e7811f38b83",
  "TruckloadData": {
    "PlantID": 566532,
    "TruckloadIDCQ": 680874,
    "Truckload_Number": "24654253",
    "Batching_DateTime_UTC": "2026-03-23T11:43:17Z",
    "LoadStart_UTC": "2026-03-23T11:43:17Z",
    "LoadEnd_UTC": null,
    "PourStart_UTC": "2026-03-23T12:53:00Z",
    "PourEnd_UTC": "2026-03-23T13:04:00Z",
    "AtJobsite_UTC": "2026-03-23T12:35:47Z",
    "ToJobsite_UTC": "2026-03-23T11:52:58Z",
    "ToPlant_UTC": "2026-03-23T13:07:59Z",
    "AtPlant_UTC": "2026-03-23T13:51:55Z",
    "Batching_Volume": 7.5,
    "Batching_Volume_Unit": "M3",
    "TruckIDCQ": 6510,
    "Truck_Code": "2553MWG",
    "Truck_PlateNr": null,
    "DriverName": null,
    "LoadingPoint": null,
    "BatchType": null,
    "JobsiteIDCQ": 676026,
    "Jobsite_ID": "0081945053",
    "Jobsite_Description": "CO MONCADA 3T50 CEU SAN PABLO",
    "Jobsite_Address": null,
    "Jobsite_CustomerName": "FCC CONSTRUCCION, S.A.",
    "Jobsite_Lat": -0.3886266,
    "Jobsite_Lon": null,
    "MixDesignIDCQ": 675729,
    "MixDesign_ID": "20334853",
    "MixDesign_Code": "2-025-4-C-28-03-0-G-033-C2",
    "MixDesign_Description": "HA-25/B/20/XC2",
    "MixDesign_MixType": null,
    "MixDesign_Grade": null,
    "MixDesign_SlumpClass": null,
    "SlumpBoundaries": {
      "DateFrom": "1900-01-01T00:00:00Z",
      "DateTo": "2100-01-01T00:00:00Z",
      "TargetValue": 125.0,
      "TargetUnitID": 203,
      "TargetUnitXID": 0,
      "Boundaries": {
        "LO_OUT": null,
        "LO_DANGER": 105.0,
        "LO_WARNING": null,
        "HI_WARNING": null,
        "HI_DANGER": 145.0,
        "HI_OUT": null
      },
      "Ranges": [
        {
          "From": 105.0,
          "To": 145.0,
          "Expr": "OK"
        }
      ]
    },
    "MixDesign_ExposureClass": null,
    "MixDesign_MaxAggregateSize": null,
    "MixDesign_MaxAggregateSize_Unit": "MM",
    "MixDesign_Target_Slump": 125.0,
    "MixDesign_Target_Slump_Unit": "MM",
    "MixDesign_Target_AirPercent": null,
    "MixDesign_Target_WCRatioMax": null,
    "Components": [
      {
        "MaterialIDCQ": 675695,
        "Material_ID": "1401455211",
        "Material_Code": "CG1",
        "Material_Name": "CEM II/B-M (S-L) 42,5 R",
        "Material_Type": "cement",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 277.0,
        "Quantity_Target_SSD": 2077.5,
        "Quantity_Target_Adjusted": 2077.5,
        "Quantity_Actual": 2076.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.0,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      },
      {
        "MaterialIDCQ": 675699,
        "Material_ID": "1401453149",
        "Material_Code": "GC4NP",
        "Material_Name": "GRAVA CALIZA 12/20 NOU PATERNA",
        "Material_Type": "coarse aggregate",
        "Material_SpecificGravity": null,
        "Quantity_MixDesign": 618.0,
        "Quantity_Target_SSD": 4637.25123,
        "Quantity_Target_Adjusted": 4660.554,
        "Quantity_Actual": 4663.0,
        "Quantity_Unit": "KG",
        "Moisture_Percent": 0.005,
        "Absorption_Percent": 0.0,
        "ManualAddition": false,
        "LoadOrder": 0
      }
    ],
    "Comments": ""
  },
  "FromExcel": false
}